My Account Menu
My Account Menu

Refine results

General healthcare

Product
Product Type
Description
High Consistency Rubbers - Medtech
Two-part silicone elastomer system
Cures with heat via addition-cure chemistry
Has a non-tacky surface and no volatile by-products or peroxide residues
Strained through a 400-mesh screen (minimum)
1:1 Mix Ratio (Part A: Part B)
Coatings/Dispersions - Medtech
Two-part medium viscosity silicone elastomer dispersed in heptane
Cures via addition-cure chemistry
1:1 Mix Ratio (Part A: Part B)
Coatings/Dispersions - Medtech
The silicone is polydimethylsiloxane polymer that cures at ambient room temperature and adheres to various substrates
Cures at room temperature upon exposure to atmospheric moisture
Soft Silicone Adhesives
A clear silicone gel
100% silicone solids (solvent-less)
A low viscosity liquid that cures to a soft, high tack silicone gel
1:1 Mix Ratio (Part A: Part B)
Supported with applicable biological testing
Soft Silicone Adhesives
A clear, tacky silicone gel
A medium viscosity liquid that cures to a soft silicone
1:1 Mix Ratio (Part A:B)
Soft Silicone Adhesives
A clear, tacky silicone gel
A medium viscosity liquid that cures to a soft, high penetration silicone
1:1 Mix Ratio (Part A: Part B)
Soft Silicone Adhesives
Clear, tacky, firm silicone gel
Easy mixing two-component, medium viscosity system
1:1 Mix Ratio (Part A:B)
Adhesives/Sealants - Medtech
Two-part, translucent, thixotropic, high tear strength silicone systems
MED1-4013 and MED3-4013 cure at room temperature and all three cure rapidly with the application of heat in an oven, or by a heat gun or lamp
Many bonding applications do not require the use of a silicone primer for suitable adhesion
Tin-free, does not require atmospheric moisture to cure
No curing byproducts such as acetic acid or methyl alcohol
Consistency allows products to be supplied in easy-to-use, airless side-by-side kits that eliminate mixing and deairing difficulties
MED1-4013 has a work time of ~15 minutes, MED2-4013 has a minimum work time of 15 hours, and MED3-4013 has a minimum work time of 60 minutes
MED1-4013 & MED3-4013 cure in less than 24 hours at room temperature
Adhesives/Sealants - Medtech
Two-part, translucent, thixotropic, high tear strength silicone systems
MED1-4013 and MED3-4013 cure at room temperature and all three cure rapidly with the application of heat in an oven, or by a heat gun or lamp
Many bonding applications do not require the use of a silicone primer for suitable adhesion
Tin-free, does not require atmospheric moisture to cure
No curing byproducts such as acetic acid or methyl alcohol
Consistency allows products to be supplied in easy-to-use, airless side-by-side kits that eliminate mixing and deairing difficulties
MED1-4013 has a work time of ~15 minutes, MED2-4013 has a minimum work time of 15 hours, and MED3-4013 has a minimum work time of 60 minutes
MED1-4013 & MED3-4013 cure in less than 24 hours at room temperature
Adhesives/Sealants - Medtech
Two-part, translucent, thixotropic, high tear strength silicone system
Cures at room temperature and will cure rapidly with the application of heat in an oven, or by a heat gun or lamp
Many bonding applications do not require the use of a silicone primer for suitable adhesion
Tin-free, does not require atmospheric moisture to cure
No curing byproducts such as acetic acid or methyl alcohol
Consistency allows product to be supplied in easy-to-use, airless side-by-side kits that eliminate mixing and deairing difficulties
Work time of ~ 15 minutes
Cures in less than 24 hours at room temperature
Cures via addition-cure chemistry
1:1 Mix Ratio (Part A: Part B)
Soft Silicone Adhesives
A two-part platinum, addition cured, low viscosity liquid that cures to a soft silicone gel suitable for applications requiring temporary adhesion.
100% silicone solids (solvent-less)
1:1 Mix Ratio (Part A: Part B)
Supported with applicable biological testing
Primers - Medtech
Specially formulated primer
Easy to use, air-drying, one-part primer designed for use with platinum-cured systems
One-component primer supplied in Isopropyl Alcohol requires no mixing
Flash Point (TCC) of 12°C (53°F)
Convenient container sizes yield less waste
Lower Volatile Organic Compound (VOC) content
Primers - Medtech
Easy to use, air-drying, one-part primer designed for use with platinum-cured systems where conventional silicone primers are insufficient
One-component primer supplied in VM&P Naphtha requires no mixing
Flash Point (TCC) of 17°C (63°F)
Convenient container sizes yield less waste
Primers - Medtech
Specially formulated primer
One-component primer supplied in VM&P Naphtha requires no mixing
Easy to use, air-drying, one-part primer designed for use with condensation cured systems where conventional silicone primers are insufficient
Flash Point (TCC) of 17°C (63°F)
Convenient container sizes yield less waste
Primers - Medtech
Specially formulated primer
One-component primer supplied in VM&P Naphtha requires no mixing
Easy to use, air-drying, one-part primer designed for use with platinum-cured systems where conventional silicone primers are insufficient
Flash Point (TCC) of 17°C (63°F)
Convenient container sizes yield less waste
Primers - Medtech
Specialty formulated primer
One-component primer supplied in VM&P Naphtha requires no mixing
Easy to use, air-drying, one-part primer designed for use with platinum-cured systems on polycarbonates
Flash Point (TCC) of 17°C (63°F)
Convenient container sizes yield less waste
Showing 1 to 16 of 152 entries